<LOGO>
FM Transmitter Measurement Report
Created: 2026-03-03 03-18-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 46 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.4 kHz 68 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 64 kHz 19148 0,1985
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,5 dBr 2,03 dBr 4,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 3:18, 3.03.2026
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6201, 6203, 6207, 6205
FM Scope Max at: 64 kHz MIN: 11 kHz % above 76 kHz: 0,1985 Acquired: 2026/03/03 3.17.49 Total samples: 19148 Equivalent time: 0:15:57 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,8 dBr MIN: 0,5 dBr AVE: 2,03 dBr % above 12,2 dBr: 0,0 Last value: 0,8 dBr (2026/03/03 3.17.49) 03.04 03.06 03.08 03.10 03.12 03.14 03.16 0 2 4 Pm [dBr]